Blaze Vault Data Centre

Our data centres are designed to provide the best possible operating environment for your IT and network equipment. Our investment in critical infrastructure gives you the piece of mind to concentrate on running your business.

Equipped with a wide range of state-of-the art equipment, our data centres are designed to ensure the security and continued operation of your IT equipment. This equipment includes:

Power

A physically separate energy centre houses the incoming electricity supply and feeds power to the data centre. Mains switch boards housed in the energy centre feed power to the UPS systems housed in the data centre. The fully redundant UPS systems operating in N+1 configuration provide a continuous stable and filtered power supply to our equipment. In case of a mains failure Two 2MVA diesel generators are able to support the entire load of the data centre. Underground bulk fuel storage means the site has 7 days autonomy in the event of a mains failure.

Cooling

The data centre utilises a high capacity DX cooling system with roof mounted chillers. Refrigerants used are non-ozone depleting. A Close control in room air handling units feed air into the data centre at a constant 20 degrees C. With full redundancy in the cooling system we can take out any one unit and continue to maintain optimum operating temperatures. High capacity floor grilles ensure sufficient air flow to cool racks of up to 4kW. All the racks are laid out within the data centre using hot and cold aisles to optimise the cooling effect and ensure that your equipment is not drawing hot air exhaust of others.

Security

Trained security personnel maintain a 24/7/365 on site presence and carry out routine security checks. External Cameras and motion sensors cover the exterior perimeter of the data centre and are monitored by on site staff. Access to the data centre is protected by a sophisticated proximity fob system meaning all access events and movement within the data centre is logged and tracked. In addition security at the rack level can be enhanced by the addition of digital locks to rack doors

Fire Protection

VESDA (very early smoke detection apparatus) and conventional smoke alarms are installed and continuously sample the air both above and below the data centre floor. VESDA monitors the entire progression of a fire - easily detecting fire long before smoke is visible and long before any other forms of detection. Fire detection apparatus is connected to a dual stage alarm system giving engineers full warning before activation of fire suppression systems. An FM200 fire suppression system protects all installed equipment against fire. FM200 works by removing heat energy from fire, not oxygen from the environment. FM200 absorbs heat from the flame zone and interrupts the chemical chain reaction of the combustion process.